Sandia National Laboratory Air-Cooled Chiller Conversion

Sandia National Laboratory Air-Cooled Chiller Conversion

Miyamoto International provided mechanical, electrical, plumbing and structural engineering services to replace three existing 350-ton water-cooled chillers with two new 450-ton air-cooled chillers for the Central Utility Plant upgrade at Building 907. To increase water conservation at the campus, the existing concrete basin cooling tower was eliminated and replaced with energy-efficient air-cooled chillers. New piping and redundant pumping systems were also provided for increased system reliability and maintenance capabilities. The design involved converting an antiquated constant volume chilled water pumping system into variable flow to optimize cooling load demands. This required a DDC control system upgrade for the National Combustion Facility into the campus Siemens P1-protocol system. The scope of work also included civil engineering to re-grade the surrounding area to create a secure expanded equipment yard.

Team Members

No data was found

Client

Sandia National Laboratory

Year

2019

Scale

5,500 SF

Location

Livermore, CA

Sandia National Laboratory Air-Cooled Chiller Conversion

Miyamoto International provided mechanical, electrical, plumbing and structural engineering services to replace three existing 350-ton water-cooled chillers with two new 450-ton air-cooled chillers for the Central Utility Plant upgrade at Building 907. To increase water conservation at the campus, the existing concrete basin cooling tower was eliminated and replaced with energy-efficient air-cooled chillers. New piping and redundant pumping systems were also provided for increased system reliability and maintenance capabilities. The design involved converting an antiquated constant volume chilled water pumping system into variable flow to optimize cooling load demands. This required a DDC control system upgrade for the National Combustion Facility into the campus Siemens P1-protocol system. The scope of work also included civil engineering to re-grade the surrounding area to create a secure expanded equipment yard.

Client

Sandia National Laboratory

Year

2019

Scale

5,500 SF

Location

Livermore, CA

More Projects

DOD/Federal

Schofield Barracks Quad A Renovation

View Project

Aviation, Retrofit, Seismic Retrofit/Heritage Renovation

LAX Theme Building

Los Angeles, CA

The futuristic LAX Theme Building, a Space Age icon at Los Angeles’ airport, was at [..]

View Project

Hero Section (1)

Lab and Science, Office

Burlingame Point

Burlingame, CA

Burlingame Point is a $400-million, 18-acre waterfront development that includes four mid-rise buildings, a six-story [..]

View Project

Healthcare, Office, Tilt-Up

Santa Rosa Medical Office Building

Santa Rosa, CA

Sutter Santa Rosa is a 80,000-SF, three-story concrete tilt-up building on conventional continuous and isolated [..]

View Project

Mixed-use, Office, Parking

The Scattergood Unit 3 Repowering Project

Los Angeles, CA

The Scattergood Unit 3 Repowering Project was, and is, the first major step toward Los [..]

View Project

Civic, Retrofit

Yuba City Fire Station #4 Retrofit

Yuba City, CA

Miyamoto was commissioned to perform an evaluation of the Structural Code Deficiencies of Yuba City [..]

View Project

Save lives, impact economies.

what we’re up to

Latest News & Updates

Subscribe to learn about new the latest in engineering news, solutions, and updates.

We care about your data in our privacy policy.