The post-earthquake sustainability of the Margarine Production Unit of the Unilever Çorlu Facility in Tekirdağ, Çorlu, Turkey was evaluated by Miyamoto engineers. The production unit consists of three reinforced concrete buildings that are connected by steel trusses. The buildings did not meet the seismic performance requirements of Turkish Earthquake Code. Since the buildings are vital for production, a retrofit design with minimum business interruption was implemented. In the retrofit design, viscous dampers were used to mitigate the weak direction of the buildings. Out of 10 dampers total, eight were used in a diagonal bracing configuration and two were used horizontally in a chevron brace configuration. The latter configuration was selected where diagonal bracing clashed with mechanical equipment. Damping force capacities of the dampers are 500kN for horizontal and 750kN for diagonal dampers. This is a highly efficient solution for damping earthquake forces.

Team Members

No data was found

Client

Unilever

Year

2016

Scale

3,400 m2

Location

Tekirdağ, Çorlu, Turkey

Unilever Çorlu Margarine Production Building Seismic Retrofitting with Viscous Dampers

The post-earthquake sustainability of the Margarine Production Unit of the Unilever Çorlu Facility in Tekirdağ, Çorlu, Turkey was evaluated by Miyamoto engineers. The production unit consists of three reinforced concrete buildings that are connected by steel trusses. The buildings did not meet the seismic performance requirements of Turkish Earthquake Code. Since the buildings are vital for production, a retrofit design with minimum business interruption was implemented. In the retrofit design, viscous dampers were used to mitigate the weak direction of the buildings. Out of 10 dampers total, eight were used in a diagonal bracing configuration and two were used horizontally in a chevron brace configuration. The latter configuration was selected where diagonal bracing clashed with mechanical equipment. Damping force capacities of the dampers are 500kN for horizontal and 750kN for diagonal dampers. This is a highly efficient solution for damping earthquake forces.

Client

Unilever

Year

2016

Scale

3,400 m2

Location

Tekirdağ, Çorlu, Turkey

More Projects

Education

Southwestern College Instructional Complex 1

Chula Vista, CA

The Southwestern College’s Instructional Complex 1 addresses the demand for highly effective general-use instructional space [..]

View Project

Entertainment

Channel 24 

Sacramento, CA

Located on the southwestern corner of 24th and R streets, Channel 24 is a new [..]

View Project

Civic, DOD/Federal

Ronald Reagan Federal Building U.S. Courthouse

Santa Ana, CA

As the largest government building in Orange County, the 10-story Ronald Reagan Federal Building uses [..]

View Project

Commercial, Lab and Science

Verily Campus Lab and Office Buildings

South San Francisco, CA

This project involved designing the exterior Buckle Restrained Braced Frame (BRBF) lateral system for two [..]

View Project

Aviation

Regional Intermodal Transportation Center

Burbank, CA

Within the scope of the Regional Intermodal Transportation Center, Miyamoto International was responsible for designing [..]

View Project

Adaptive Reuse

Crossroads School for Arts & Sciences Pac Air Building Adaptive Reuse

Santa Monica, CA

Crossroads School for Arts & Sciences is wholly dedicated to serving the “greater community.” By [..]

View Project

Save lives, impact economies.

what we’re up to

Latest News & Updates

Subscribe to learn about new the latest in engineering news, solutions, and updates.

We care about your data in our privacy policy.