Caracas, Venezuela / Field Update
Miyamoto International field engineers continued structural assessments and coordination with local authorities in Caracas and Chacao.

CARACAS, VENEZUELA — Miyamoto International field engineering support continued in Caracas and Chacao, where teams began translating early observations into practical guidance for local officials, emergency managers, and rescue operations.
Initial observations in Caracas suggested that the city was not uniformly devastated, but many older mid-rise and high-rise buildings showed damage to facade walls, infill walls, finishes, and interior partitions. Buildings requiring closer review were prioritized through street-level visual triage and targeted structural assessments.
Coordination With Local Authorities
Miyamoto’s field team met with representatives from Miranda state and local contacts in Chacao to discuss immediate assessment needs. The conversation focused on how to organize damage evaluations, how to collect and manage field information, and how to avoid common post-earthquake assessment gaps seen in prior disasters.
Officials requested a priority assessment of a government structure adapted for school use and serving approximately 5,000 students. After a demonstration-style assessment process, including exterior review, interior access, and identification of the structural system and damage condition, access restriction was recommended due to observed instability conditions.
Building Assessments in Caracas and Chacao
During initial street-level triage in Chacao, field observations identified buildings requiring detailed inspection due to uncertainty around their lateral systems, visible severe damage, or potential collapse risk. Other buildings appeared to have more limited or repairable damage.
Across the initial route, many observed buildings showed some level of damage, primarily to nonstructural elements. A smaller subset appeared potentially hazardous and in need of priority review. These observations remain preliminary and are intended to support early response decisions.
Petunia Collapse Site
The team also reached the Petunia building in Los Palos Grandes, a 16-story structure that collapsed in a pancake pattern with lateral displacement toward the street. The collapse affected occupants, pedestrians, and vehicles, while debris created concern for the adjacent building that remained standing.
On site, field engineering support focused on rescue-team safety, review of the collapse condition, and technical discussion with local civil engineers supporting search and rescue operations. Recommendations included monitoring the adjacent structure and identifying practical ways to track movement during ongoing rescue work.
Continuing Assessments
Later field work included assessment of a relatively new building with significant cracking in lower levels. The observations raised important questions about observed seismic performance, construction practice, and differences between expected behavior under current code assumptions and actual building response.
The next phase of field work is expected to move toward La Guaira, where reports indicate broader damage across many structures.